A vendor's binary variable dump needs its type table, not a fixed field width

Domain: fanuc · Evidence E1 — Maintainer reviewed
binaryreverse-engineeringschemasentinelparsing

Summary

Decoding a controller's binary variable files (the dumps a backup carries for its variable

Problem

Decoding a controller's binary variable files (the dumps a backup carries for its variable namespaces) produced plausible-looking garbage: numbers in the wrong places, strings cut short, and no way to tell an uninitialized variable from a real value.

Root Cause

Three assumptions that hold for one row and not for the file:

  1. Width comes from the type, not from the reader. Scalars are 4 bytes for some types and 2 or 1 for others (SHORT, BYTE); reading everything as 4 bytes shifts every field after the first narrow one. That is why numbers look random rather than absent — the reader stays in bounds and simply reads the wrong window.
  2. Strings are padded to an even stride, so their step is 2 + roundup(maxlen + 1, 2), not 2 + maxlen. Off by one byte per string accumulates into full misalignment.
  3. Sentinels are values. 0x7FFFFFFF, 0x7FFF and a NaN payload mean "uninitialized"; compared as numbers they are just very large or very odd, so an uninitialized BOOLEAN reads as true.

The container is a compressed stream with a declared length — and it is structurally the same as the format the vendor's program files use, so the same decompressor applies. Reading the declared instance size and checking that the fields you decoded sum to it is the cheapest self-check: a width table that is wrong will not add up.

Fix

Drive the reader from the type table and normalise sentinels before comparing:

WIDTH = {"BYTE": 1, "SHORT": 2, "INT": 4, "REAL": 4, "BOOL": 4}

def stride_for_string(maxlen: int) -> int:
    return 2 + ((maxlen + 1 + 1) // 2) * 2        # 2-byte length prefix, even padding

def read_scalar(buf, off, type_name):
    w = WIDTH[type_name]
    raw = buf[off:off + w]
    if type_name == "BOOL":
        value = int.from_bytes(raw, "big")
        return (None if value == 0x7FFFFFFF else bool(value)), off + w   # sentinel first
    return int.from_bytes(raw, "big"), off + w

Then validate against the vendor's own text export, per namespace, and report the leaf count. Measured on one backup: 3,982 / 38,472 / 3,698 / 8,554 leaves across four namespaces, all matching — a fixed-width reader matches far fewer and, worse, fails silently on the ones it "reads".

Verification

$ python3 decode.py --file sysmast.sv --compare vendor-export.txt
leaves 3982/3982 matched
instance size 0x1A40: decoded fields sum to 0x1A40   <- the width table is consistent

If the decoded fields do not sum to the declared instance size, the table still has a wrong entry — that check catches the misalignment before any value is trusted.